Projekt · Dnr 2020-04841 · Källa: Vinnova

Automated Blood Volume Measurement on Head CT

Koordinator
Region Skåne, VO Bild och Funktion
Projekttid
2021-05-15 till 2022-09-15 (avslutat)
Beviljat bidrag
275 000 SEK
Diarienummer
2020-04841

Beskrivning

The aim of this study was to validate a novel automated software (qERNCCT by Qure.ai) for quantification of intracerebral bleedings (ICH) on CT. Manual segmentation was compared to qERNCCT in 1649 ICH patients selected from the Swedish Stroke Register. The qER-NCCT fully automated volume measurement had excellent agreement with manual segmentation. Implementing such automated software for ICH volume measurement could improve diagnostics and prognostication considerably since exact volumetric measurement currently is an unmet medical need in routine healthcare. The main publication for this project (Accuracy of automated intracerebral hemorrhage volume measurement on non-contrast computed tomography; a Swedish Stroke Register cohort study Amir Hillal, Gabriella Sultani, Birgitta Ramgren, Bo Norrving, Johan Wassélius and Teresa Ullberg) is currently in press for Neuroradiology. The project has also generated 3 additional manuscripts that are in preparation and one congress abstract at ECR 2022.

Öppna hos Vinnova

Hittar Vinnova inte sidan? Sök på diarienumret hos Vinnova.

Liknande

  1. Volumeer - Revolutionär Sepsisprovskvalitet för livräddande effekt

    Volumeer AB · 2023-10-30 · 122 585 SEK · Projekt

    The overall aim is the development of a device for real-time blood volume measurement, avoidance of contamination and overall standardization of the sampling process to avoid user error. We have reached the stage of being able to produce a minimum viable product for further usability and lab-testing…

  2. E!10253, CD-CARD, Diagnostic product for rapid HIV-patient testing, Getica AB

    GETICA AB · 2016-03-01 · 4 615 388 SEK · Projekt

    Measurements of CD4 receptors on the surface og lymphocytes in whole blood samples by means of flow cytometry technology is the classical method for monitoring treatment of HIV infected patients. The reagent and the equipment are expensive, and may patiens do not have access to the technologies. Get…

  3. Ultrasound and Photoacoustic Imaging System

    Göteborgs universitet · 2026-03-16 · sista anbudsdag 2026-04-13 · 3 500 000 SEK · Upphandling

    This procurement covers a Ultrasound and Photoacoustic Imaging System, for imaging and measurements of macro- and micro-circulatory changes in organs of animals using high-resolution ultrasound together with doppler-ultrasound tailored for small to large animals. Key technical criteria include high …

  4. Serial Block-Face Scanning Electron Microscope (SBF-SEM)

    Göteborgs universitet · 2026-04-15 · sista anbudsdag 2026-05-14 · 6 000 000 SEK · Upphandling

    The procurement covers a Serial Block-Face Scanning Electron Microscope (SBF-SEM) for automated three-dimensional imaging of the ultrastructure of biological specimens embedded in resin (System), as specified in the RFT. The System will enable long-term automated acquisition of large volumetric data…

  5. Serial Block-Face Scanning Electron Microscope (SBF-SEM)

    Göteborgs universitet · 2026-07-13 · 5 800 000 SEK · Tilldelning

    The procurement covers a Serial Block-Face Scanning Electron Microscope (SBF-SEM) for automated three-dimensional imaging of the ultrastructure of biological specimens embedded in resin (System), as specified in the RFT. The System will enable long-term automated acquisition of large volumetric data…