Tilldelning · Källa: TED – Tenders Electronic Daily

High energy X-ray instrumentation (hexapod, detectors etc) for the Swedish beamline

Köpare
Kungliga Tekniska högskolan
Vinnare
Hamamatsu Photonics Norden AB, Nordic Biolabs Aktiebolag, DECTRIS AG, Optique Peter, SYMETRIE
Publicerad
2024-04-18
Värde
11 000 000 SEK
CPV-koder
38000000 Laboratorieutrustning, optisk utrustning och precisionsutrustning (exkl. glas)
Annons-id
229321-2024

AI-sammanfattningen tas fram …

Beskrivning

A part with general requirements that all tenderers have to answer. The purpose of the positioning hexapod system is to support a wide range of sample environments, especially heavy sample environments, and position these accurately relative to the SMS beamline’s X-ray beam. This positioning hexapod system comprises a system for moving the hexapod, e.g. an airpad system. The purpose of this X-ray detector (part of the detector portal 1) is to capture a large scattering vector range for diffraction measurements. The crucial capability is the large scattering vector range, with the frame rate not being the prime concern. The purpose of these X-ray detector(s) (part of detector portal 2) is to capture images at a very high frame rate for diffraction measurements. The crucial capability is the frame rate, with the captured scattering vector range not being the prime concern. The purpose of the Detector portal 3 is to perform X-ray imaging (radiography) and fluorescence measurements. This equipment is for the X-ray radiography. The intent is to have the possibility to perform high-resolution imaging and high frame rate imaging with the same instrument, either with 2 motorized switchable setups (option 1) or by manual changing (option 2). This optical camera will be used to record the radiography image generated by the X-ray camera setup described previously. This detector will be used to perform X-ray fluorescence spectroscopy in relatively low energy ranges. This equipment aims to increase the rotation travel range around the vertical axis of the hexapod to 360°. Since the available height below the X-ray beam and above the hexapod top surface is limited, this rotating table must be removable.

Öppna originalannonsen hos TED

Liknande

  1. Table top X-ray

    Lunds universitet · 2024-01-09 · 3 800 000 SEK · Tilldelning

    The objective of this procurement is to obtain an instrument setup capable of high resolution X-ray absorption fine structure (XAFS) spectroscopy at the K-absorption edges of Ti, Cr, Mn, Fe, Co, Ni, Cu, and the L3 edge of Ir and Ce.

  2. X-ray microcomputed tomography system to the Ångström laboratory

    Uppsala universitet · 2025-08-11 · sista anbudsdag 2025-09-08 · 11 000 000 SEK · Upphandling

    The Department of Materials Science and Engineering at Uppsala University intends to acquire a standalone laboratory X-ray microcomputed tomography (μCT) system for high resolution, high contrast non-destructive 3D imaging of objects, comprising a radiation shielding cabinet, X-ray source/s, 2D dete…

  3. Multiphoton imaging system

    Karolinska Institutet · 2024-12-10 · Tilldelning

    The research group of Stefanos Stagkourakis will carry out a project focused on all-optical investigations that provide the capability of imaging and manipulating neuronal activity at the same time. Specifically, multiphoton imaging of Ca2+ and voltage indicators will be used to study neuron activit…

  4. X-ray Diffractometer for rapid and absolute structure determination

    Lunds universitet · 2026-07-16 · 7 000 000 SEK · Upphandling

    State of the art X-ray diffractometer. Rapid data collection (area detector). Cryosystem (liquid N2). Must have copper radiation.

  5. Förhandlat Förfarande - Hygro-Thermal-Mechanical In-Situ XCT stage

    Luleå tekniska universitet · 2025-06-16 · 1 603 500 SEK · Tilldelning

    The purpose of this procurement is to acquire an in-situ module for microtomography that allows for controlled variations in temperature, humidity, and mechanical load during analysis. The equipment will be used to study the behavior of samples in different environmental conditions. This need is sha…